Tapcon®
XL Anchors
|
| DESCRIPTION
/ SUGGESTED SPECIFICATIONS |
|
 
|
Tapcon
XL Anchors
|
|
Miami-Dade County – #07-1126.10
Florida Building Code
|
|
|
Tapcon
XL Anchor |
| Diameter............5/16" |
Thread Form.....Reverse Hi-Lo® |
| Point Type.........Nail |
Finish.................UltraShield™ or *White UltraShield™ |
| Head Style.........High button with TORX T-40 Drive |
| XLs are packed 100 pieces per master carton. |
|
RECOMMENDED
TAPCON LENGTH
In. (mm) |
PART NO.
1/4" HEX HEAD |
FINISH |
BIT LENGTH
In. (mm) |
STRAIGHT SHANK
BIT FOR 1/4" TAPCON
PART NO. |
2-1/4 (57.2) |
3395902 |
Ultra Shield |
6-3/4” SDS drill bit with hex |
3394910 |
2-1/4 (57.2) |
3397902 |
*White Ultra Shield |
6-3/4” SDS drill bit with hex |
3394910 |
2-3/4 (69.9) |
3398902 |
*White Ultra Shield |
6-3/4” SDS drill bit with hex |
3394910 |
|
|
PART NO. |
DESCRIPTION |
CARTON QTY |
3401910 |
Condrive® XL Installation Tool with MegaGrip™ Bit Holder with TORX® T-40 Bit Tip |
10 per master carton |
3400910 |
MegaGrip™ Magnetized Bit Holder with TORX T-40 Bit Tip |
10 per bag |
3394910 |
1/4” x 6-3/4” SDS Tapcon Drill Bit with Hex |
1 piece per tube |
Tapcon XL Anchors must be installed using all Red Head system components (Tapcon XL Anchors, Condrive XL Installation Tool and Tapcon Drill Bits) in order to qualify for ITW Red Head system support. |
|
Back to the top |
| |
|
|
Tapcon
XL Anchor |
Ultimate Tension and Shear Values (Lbs/kN) in Concrete |
ANCHOR
DIA.
In. (mm) |
MIN. DEPTH OF
EMBEDMENT
In. (mm) |
EDGE DISTANCE | f'c = 3000 PSI (20.7 MPa) |
TENSION
Lbs. (kN) |
SHEAR
Lbs. (kN) |
| 5/16 (7.9) |
1-1/4 (31.8) |
1-9/16 (39.7) |
1,050 (4.7) |
1,330 (5.9) |
| 2-3/16 (55.6) |
1,205 (5.4) |
1,725 (7.7) |
| 1-3/4 (44.5) |
1-9/16 (39.7) |
2,020 (9.0) |
1,530 (6.8) |
| 2-3/16 (55.6) |
2,250 (10.0) |
2,505 (11.1) |
| 2-1/4 (57.2) |
1-9/16 (39.7) |
2,850 (12.7) |
1,955 (8.9) |
| 2-3/16 (55.6) |
3,120 (13.9) |
3,250 (14.4) |
Safe working loads for single installation under static loading should not exceed 25% of the ultimate load capacity.
|
|
|
Tapcon
Maxi-Set Anchor |
Ultimate Tension & Shear Values in Concrete Masonry Units |
ANCHOR
DIA.
In. (mm) |
ANCHOR
EMBEDMENT
In. (mm) |
EDGE
DISTANCE
In. |
HOLLOW CORE1 |
GROUT-FILLED2 |
TENSION
Lbs. (kN) |
SHEAR
Lbs. (kN) |
TENSION
Lbs. (kN) |
SHEAR
Lbs. (kN) |
| 5/16 (7.9) |
1-1/4 (31.8) |
4 |
1,045 (4.6) |
2,280 (10.1) |
1,045 (4.6) |
2,280 (10.1) |
| |
1-3/4 (44.5) |
4 |
NOT RECOMMENDED |
NOT RECOMMENDED |
1,950 (8.7) |
2,825 (12.6) |
| |
2-1/4 (57.2) |
4 |
NOT RECOMMENDED |
NOT RECOMMENDED |
3,770 (16.8) |
3,140 (14.0) |
Safe working loads for single installation under static loading should not exceed 25% of the ultimate load capacity.
1 CMU = 1,600 PSI minimum compressive strength.
2 CMU = 1,600 PSI minimum compressive strength with 2,000 PSI grout. |
|
|
| |
|
| |
Back to the top
|
|
| |
|
INSTALLATION INSTRUCTIONS |
MegaGrip Adjustable
Magnetic Bit Holder with
TORX T-40 Bit Tip
Part Number 3400910

|
| Read instructions
before using (installation)! |
 |
WARNING! |
If there are any questions concerning
proper installation, applications or appropriate use of this product,
please call our Technical Services Department at 1-800-899-7890. Failure
to follow these instructions can result in serious personal injury. |
|
| 1. |
Select proper fastener – diameter/head
style/length. |
|
a) Use selection chart to
choose proper length. |
| 2. |
Drill Hole – use selection chart to determine drill bit length and depth of hole. |
|
a) Choose appropriate drill bit based upon diameter of Tapcon Anchor. |
|
b) Drill hole minimum ¼” deeper
than Tapcon Anchor to be embedded.
Minimum anchor embedment: 1”
Maximum anchor embedment: 1-3/4” |
| 3. |
Insert the adjustable MegaGrip bit tip holder in the small opening of sleeve. Slide
the open end of the Condrive XL Installation Tool sleeve over the drill bit and snap
in place. |
| 4. |
Drive anchor using MegaGrip adjustable magnetic bit holder with TORX T-40 bit tip |
|
 |
WARNING! |
Failure to wear safety glasses with side shields can result in serious personal injury. Always wear ANSI compliant eye protection (ANSI Z87.1-2003). |
 |
WARNING! |
Using the wrong size drill bit will affect performance
values and may cause faliure. |
|
Back to the top |
|
|
|
|