header

or go to the Advance Search
QuickMenu Save Document
redselec01a.jpg (11704 bytes)

Anchors for Concrete Applications

ANCHOR
TYPE
KEY
FEATURES
SIZE RANGE
(Inches)
CORROSION
RESISTANCE
PERFORMANCE HEAD STYLES APPROVALS/
LISTINGS
Trubolt+®
Seismic Wedge Anchors
redselec01f.jpg (13306 bytes)
Product Information
Installation Steps
Selection/Ordering Information
Performance Data
Approvals/Listings
Suggested Specification
Zinc-plated carbon steel to ASTM B633, SC1, Type III

Pullout strength of 4,980 lbs in 2,500 psi Cracked Concrete (1/2" diameter) Hex nut

ICC Evaluation Service, Inc. # ESR-2427
-Category 1 performance rating
-2006 IBC and 2009 IBC compliant
-Meets ACI 318 ductility requirements
-Tested in accordance with ACI 355.2 and ICC-ES AC193
-Listed for use in seismic zones A, B, C, D, E, & F
-3/8", 1/2", 5/8" and 3/4" diameter anchors listed in ESR-2427

City of Los Angeles - #RR25867

sq2006 IBC & 2009 IBC Compliant

sqAll seismic zone (A-F) and cracked concrete approved

Fully-threaded

Length ID head stamped

Through-fixture fastening

Diameter: 3/8, 1/2 & 5/8

Length:
3 – 8-1/2

Trubolt®
Wedge Anchors
redselec01f.jpg (13306 bytes)
Product Information
Installation Steps
Selection/Ordering Information
Performance Data
Approvals/Listings
Suggested Specification
trubolt sqZinc-plated carbon steel to ASTM B633, SC1, Type III

sqHot dipped galvanized to ASTM A -153

sqType 304 and
316 stainless steel
Ultimate Pullout Performance in 4000 psi Concrete up to 26,540 lbs. (1" diameter) Hex nut

Tie-Wire version
ICC Evaluation Service, Inc. # ESR-2251
- Category 1 performance rating
- 2006 IBC compliant
- Meets ACI 318 ductility requirements
- Tested in accordance with ACI 355.2 and ICC-ES AC193
- For use in seismic zones A & B
- 1/4", 3/8" & 1/2" diameter anchors listed in ESR-2251

Underwriters Laboratories

Factory Mutual

City of Los Angeles - #RR2748

California State Fire Marshall

Caltrans

Meets or exceeds U.S. Government G.S.A. Specification A-A-1923A Type 4 (formerly GSA: FF-S-325 Group II, Type 4, Class 1)

sq2006 IBC Compliant

sqSeismic zone (A-B) approved

sqFully-threaded

sqLength ID head stamped

sqStainless steel clip

sqThrough-fixture fastening

Diameter:
1/4 –1

Length:
1-3/4 –12

Large Diameter Tapcon (LDT) and LDTX
Self-Threading Anchor
redselec01j.jpg (12114 bytes)
Product Information
Installation Steps
Selection/Ordering Information
Performance Data
Approvals/Listings
Suggested Specification

ldt

sqZinc-plated carbon steel to ASTM B695 & B633

sqType 410 stainless steel

sqNow with EnvireX coating.

Approved for use in ACQ lumber (Excessive content of copper in ACQ lumber may affect the anchor finish.

1,000 hours salt spray ASTM B117

Ultimate Pullout Performance in 4,000 psi Concrete up to 23,266 lbs. (3/4" diameter)

Finished bolt style

 

Florida Building Code

 

sqAnti-rotation searrated washer

sqExtra large hex washer head

sqLength ID head stamped

sqThrough-fixture fastening

LDT with Zinc Plating
Diameter:
3/8 – 3/4

Length:
1-3/4 – 6-1/4


LDTX with EnvireX Coating

Diameter:
3/8 & 1/2

Length: 3 – 5

Multi-Set II®
Drop-In Anchors
redselec01n.jpg (11770 bytes)
Product Information
Installation Steps
Selection/Ordering Information
Performance Data
Approvals/Listings
Suggested Specification

redselec01o.jpg (11550 bytes)

sqZinc-plated carbon steel to
ASTM B633, SC1, Type III

sqType 18-8 and 316 stainless steel

Ultimate Pullout Performance in 4,000 psi Concrete up to 9,480 lbs.(3/4" diameter)

sqRM: Flanged body

sqRL: Non-flanged body

sqUse any bolt or threaded rod
GSA: A-A-55614 Type 1 (Formerly GSA: FF-S-325 Group VIII)

Underwriters Laboratories

Factory Mutual

City of Los Angeles – #RR2748


California State Fire Marshal

Caltrans
sqRM: Flanged body to keep anchor flush with surface of concrete

sqRL: Non-flanged body for recessed setting

sqRX: Designed for hollow core and post tension concrete


sqCL: Designed for one-sided forming, accepts coil rod
RM – Diameter:
1/4 – 3/4
Length:
1–-3-3/16

RL – Same as
RM (above)

RX – Diameter:
3/8 & 1/2
Length: 3/4 –1

CL – Diameter:
1/2 & 3/4
Length:
2 & 3-3/16

BoaTM Coil
Expansion Anchor
redselec01r.jpg (12924 bytes)
Product Information
Installation Steps
Selection/Ordering Information
Performance Data

redselec01s.jpg (7472 bytes)
sqZinc-plated carbon steel to ASTM B633, SC1, Type III

Ultimate Pullout Performance in 4,000 psi Concrete up to 38,500 lbs. (3/4" diameter)

 

Finished bolt style

 

sqHeavy-Duty, Reusable Fastening

sqEasy installation

sqRemovable

sqHigh shear strength

sqReplacement coil available for easy re-use

Diameter:
1/2 – 3/4

Length:
3–-6-

Prima
High Expansion
Sleeve Anchors
redselec01v.jpg (12813 bytes)
Product Information
Installation Steps
Selection/Ordering Information
Performance Data

redselec01w.jpg (6358 bytes)
Sleeve – S300 Pb NFA 35561

Bolt – Grade 5 1035 carbon steel

Cone – S300 Pb NFA 35561

Coating – Zinc NFE 25009, passivation NFA 91472

Ultimate Pullout Performance in 4,000 psi Concrete up to 8,500 lbs. (1/2" diameter)

Finished bolt style
 

Lightweight Concrete, and Masonry Fastening

Easy installation

Removable fastening

Diameter:
1/4 – 1/2

Length:
2-3/8–-3-9/16

 

Dynabolt®
Masonry Sleeve Anchors
redselec01r.jpg (12924 bytes)
Product Information
Installation Steps
Selection/Ordering Information
Performance Data
Approvals/Listings
Suggested Specification

redselec01s.jpg (7472 bytes)
sqZinc-plated carbon steel to ASTM B633, SC1, Type III

sqType 304 stainless steel

Ultimate Pullout Performance in 4,000 psi Concrete up to 8,900 lbs. (3/4" diameter)

 

sqFlat head

sqHex nut

sqAcorn nut

sqTie-Wire

sqRound head

sqThreshold flat head
GSA: A-A-1922A
(Formerly GSA: FF-S-325 Group II, Type 3, Class 3)


Factory Mutual

California State Fire Marshal

sqConcrete, block and brick

sqMany choices of head styles

sqThrough-fixture fastening

sqAvailable in 304 stainless steel

 

Diameter:
1/4 – 3/4

Length:
5/8–-6-1/4

Stud
Stud Anchors
redselec01v.jpg (12813 bytes)
Product Information
Installation Steps
Selection/Ordering Information
Performance Data
Approvals/Listings
Suggested Specification

redselec01w.jpg (6358 bytes)
Zinc-plated carbon steel to ASTM B633, SC1, Type III

Ultimate Pullout Performance in 4,000 psi Concrete up to 7,520 lbs.

Hex nut
GSA: A-A-55614 Type 2 (Formerly GSA: FF-S-325 Group VIII, Type 2)

Factory Mutual

Underwriters Laboratories

California State Fire Marshal

Bottom bearing

Hammer-driven

Ideal for jacking or leveling

Easy installation

 

Diameter:
1/4 – 3/4

Length:
1-3/4–-6-1/4

 

 


NEXT PAGEanchsel01cc.jpg (8315 bytes)