ANCHOR
TYPE |
KEY
FEATURES |
SIZE
RANGE
(Inches) |
CORROSION
RESISTANCE |
PERFORMANCE |
HEAD
STYLES |
APPROVALS/
LISTINGS |
Trubolt®
Wedge Anchors
 Product
Information
Installation Steps
Selection/Ordering Information
Performance Data
Approvals/Listings
Suggested Specification |
 |
Zinc-plated
carbon steel to ASTM B633, SC1, Type III
Hot
dipped galvanized to
ASTM A -153
Type
304 and
316 stainless steel |
Ultimate
Pullout Performance in 4000 psi Concrete up to 43,300 lbs. |
Hex
nut
Tie-Wire version |
GSA:
A-A-1923A Type 4 (Formerly GSA: FF-S-325 Group II, Type 4, Class 1)
Underwriters Laboratories
Factory
Mutual
ICC
Evaluation Service, Inc. #ESR-2251 (formerly ICBO ER1372)
City
of Los Angeles #RR2748
California
State Fire Marshal
Cal
Trans
Metro-Dade
County #01-0504.12
Florida
Building Code |
Fully-threaded
Length
ID head stamped
Stainless
steel clip
Through-fixture
fastening
|
Diameter:
1/4 1
Length:
1-3/4 12
|
Large
Diameter Tapcon (LDT)
Self-Threading Anchor
 Product
Information
Installation Steps
Selection/Ordering Information
Performance Data
Approvals/Listings
Suggested Specification |
|
Zinc-plated
carbon steel to
ASTM B695 & B633
Type
410 stainless steel
|
Ultimate
Pullout Performance in 4,000 psi Concrete up to 23,266 lbs.
|
Finished
bolt style
|
ICC
Evaluation Service, Inc. #ER-5890 (3/8" and 1/2" diameter) (formerly ICBO)
City
of Los Angeles RR#25498 (3/8" and 1/2" diameter)
Metro-Dade
County #04-1025.08
Florida Building Code
|
|
Anti-rotation
searrated washer
Extra
large hex washer head
Length
ID head stamped
Through-fixture
fastening |
Diameter:
3/8 3/4
Length:
1-3/4 6-1/4
|
Multi-Set
II®
Drop-In Anchors
 Product
Information
Installation Steps
Selection/Ordering Information
Performance Data
Approvals/Listings
Suggested Specification |

|
Zinc-plated
carbon steel to
ASTM B633, SC1, Type III
Type
18-8 and 316 stainless steel |
Ultimate
Pullout Performance in 4,000 psi Concrete up to 9,480 lbs.
|
RM:
Flanged body
RL:
Non-flanged body
Use
any bolt or threaded rod |
GSA:
A-A-55614 Type 1 (Formerly GSA: FF-S-325 Group VIII)
Underwriters
Laboratories
Factory
Mutual
ICC
Evaluation Service, Inc. #ER-1372 (formerly ICBO)
City
of Los Angeles #RR2748
SBCCI
Compliance Report #9570
California
State Fire Marshal
Cal
Trans |
RM:
Flanged body to keep anchor flush with surface of concrete
RL:
Non-flanged body for recessed setting
RX:
Designed for hollow core and post tension concrete
CL:
Designed for one-sided forming, accepts coil rod |
RM
Diameter:
1/4 3/4
Length:
1-3-3/16
RL Same as
RM (above)
RX
Diameter:
3/8
Length: 3/4
CL Diameter:
1/2 & 3/4
Length:
2 & 3-3/16 |
| Dynabolt®
Masonry Sleeve Anchors

Product
Information
Installation Steps
Selection/Ordering Information
Performance Data
Approvals/Listings
Suggested Specification |
|
Zinc-plated
carbon steel to
ASTM B633, SC1, Type III
Type
304 stainless steel |
Ultimate
Pullout Performance in 4,000 psi Concrete up to 8,900 lbs.
|
Flat
head
Hex
nut
Acorn
nut
Tie-Wire
Round
head
Threshold
flat head
|
GSA:
A-A-1922A
(Formerly GSA: FF-S-325 Group II, Type 3, Class 3)
Factory
Mutual
California
State Fire Marshal
|
|
Concrete,
block and brick
Many
choices of head styles
Through-fixture
fastening
Available
in 304 stainless steel
|
Diameter:
1/4 3/4
Length:
5/8-6-1/4 |
|
Stud
Stud Anchors

Product
Information
Installation Steps
Selection/Ordering Information
Performance Data
Approvals/Listings
Suggested Specification
|
|
Zinc-plated
carbon steel to
ASTM B633, SC1, Type III
|
Ultimate
Pullout Performance in 4,000 psi Concrete up to 7,520 lbs.
|
Hex
nut
|
GSA:
A-A-55614 Type 2 (Formerly GSA: FF-S-325 Group VIII, Type 2)
Factory
Mutual
Underwriters
Laboratories
California
State Fire Marshal
|
|
Bottom
bearing
Hammer-driven
Ideal
for jacking or leveling
Easy
installation
|
Diameter:
1/4 3/4
Length:
1-3/4-6-1/4
|