Average Ultimate Tension  Loads 1,2,3 for Reinforcing Bar Installed in Solid Concrete

REINFORCING
BAR DIA.
In. (mm)
EMBEDMENT
IN CONCRETE
In. (mm)
2000 PSI (13.8 MPa)
CONCRETE
ULTIMATE TENSION
Lbs. (kN)
4000 PSI (27.6 MPa)
CONCRETE
ULTIMATE TENSION
Lbs. (kN)
ULTIMATE TENSILE AND YIELD STRENGTH
GRADE 60 REBAR
MINIMUM YIELD
STRENGTH
Lbs. (kN)
MINIMUM ULTIMATE
TENSILE STRENGTH
Lbs. (kN)
# 3 (9.5) 3-3/8 (85.7)
4-1/2 (114.3)
6,180 (27.5)
7,560 (33.6)
8,324 (37.0)
11,418 (50.8)
6,600 (29.4)
6,600 (29.4)
9,900 (44.0)
9,900 (44.0)
# 4 (12.7) 4-1/2 (114.3)
6 (152.4)
9,949 (44.3)
15,038 (66.9)
16,657 (74.1)
17,828 (79.3)
12,000 (53.4)
12,000 (53.4)
18,000 (80.1)
18,000 (80.1)
# 5 (15.9) 5-5/8 (142.9)
7-1/2 (190.5)
14,012 (62.3)
16,718 (74.4)
20,896 (93.0)
26,072 (116.0)
18,600 (82.7)
18,600 (82.7)
27,900 (124.1)
27,900 (124.1)
# 6 (19.1) 6-3/4 (171.5)
9 (228.6)
21,247 (94.5)
33,325 (148.2)
26,691 (118.7)
37,425 (166.5)
26,400 (117.4)
26,400 (117.4)
39,600 (176.2)
39,600 (176.2)
# 7 (22.2) 7-7/8 (200.0)
10-1/2 (266.7)
--           --
38,975 (173.4)
40,374 (179.6)
46,050 (204.8)
36,000 (160.1)
36,000 (160.1)
54,000 (240.2)
54,000 (240.2)
# 8 (25.4) 9 (228.6)
12 (304.8)
35,600 (158.4)
41,010 (182.4)
47,311 (210.5)
66,140 (294.2)
47,400 (210.9)
47,400 (210.9)
71,100 (316.3)
71,100 (316.3)
# 9 (28.6) 10-1/8 (257.2)
13-1/2 (342.9)
--           --
--          --
57,221 (254.5)
79,966 (355.7)
60,000 (266.9)
60,000 (266.9)
90,000 (400.4)
90,000 (400.4)
# 10 (31.8) 11-1/4 (285.8)
15 (381.0)
49,045 (218.2)
69,079 (307.3)
73,091 (325.1)
83,295 (370.5)
76,200 (339.0)
76,200 (339.0)
114,300 (508.5)
114,300 (508.5)
# 11 (34.9) 12-3/8 (314.3)
16-1/2 (419.1)
63,397 (282.0)
81,707 (363.5)
75,047 (333.8)
91,989 (409.2)
93,600 (416.4)
93,600 (416.4)
140,400 (624.6)
140,400 (624.6)

1 Allowable working loads for the single installations under static loading should not exceed 25% capacity or the allowable load of the anchor rod.
2 Ultimate load values in 2000 and 4000 psi stone aggregate concrete. Ultimate loads are indicated for the embedment shown in the Embedment in Concrete column. Performance values are based on the use of minimum Grade 60 reinforcing bar. The use of lower strength rods will result in lower ultimate tension loads.
3 SHEAR DATA: Provided the distance from the rebar to the edge of the concrete member exceeds 1.25 times the embedment depth of the rebar, calculate the ultimate shear load for the rebar anchorage as 60% of the ultimate tensile strength of the rebar.

PERFORMANCE TABLE

A7  
Acrylic Adhesive     

Recommended Edge Distance Requirements for Shear Loads

ANCHOR
DIAMETER
In. (mm)
EMBEDMENT
DEPTH
In. (mm)
CRITICAL
EDGE DISTANCE
In. (mm)
(100% LOAD CAPACITY)
INTERPOLATED
EDGE DISTANCE
In. (mm)
(80% LOAD CAPACITY)
INTERPOLATED
EDGE DISTANCE
In. (mm)
(50% LOAD CAPACITY)
MINIMUM
EDGE DISTANCE
In. (mm)
(10% LOAD
CAPACITY)
3/8 (9.5) 3-3/8 (85.7) 4-3/16 (106.4) 3-7/16 (87.3) 2-5/16 (58.7) 13/16 (20.6)
1/2 (12.7) 4-1/2 (114.3) 5-5/8 (142.9) 4-5/8 (117.5) 3-1/8 (79.4) 1-1/8 (28.6)
5/8 (15.9) 5-5/8 (142.9) 7 (177.8) 5-3/4 (146.1) 3-1/8 (79.4) 1-3/8 (34.9)
3/4 (19.1) 6-3/4 (171.5) 8-7/16 (214.2) 6-15/16 (176.2) 4-5/8 (117.5) 1-5/8 (41.3)
1 (25.4) 9 (228.6) 11-1/4 (285.8) 9-1/4 (235.0) 6-1/4 (158.8) 2-1/4 (57.2)
1-1/4 (31.8) 11-1/4 (285.8) 14-1/16 (357.2) 11-5/8 (295.3) 7-7/8 (200.0) 2-7/8 (73.0)


Combined Shear and Tension Loading — for Epcon A7 Adhesive Anchors

Allowable loads for anchors under tension and shear loading at the same time (combined loading) will be lower than the allowable loads for anchors subjected to 100% tension or shear. Use the following equation to evaluate anchors in combined loading conditions:

epcon_a7selec5a.jpg (2017 bytes) Na = Applied Service Tension Load
Ns = Allowable Tension Load
Va = Applied Service Shear Load
Vs = Allowable Shear Load

Performance Data: Page 3 of 5
Back | Next

A7 Acrylic Adhesive
Product Information and Advantages
Suggested Specifications
Applications, Features and Installation Instructions
5 oz. Specifications, Advantages and Applications
10 oz. Specifications, Advantages and Applications

Performance Data (5 pages) : Approval and Listings
Ordering Information and Estimating Tables: 28 oz. : 10 oz. : 8 oz. : 5oz.

 


copyright © 2008 Illinois Tool Works, Inc. Privacy Policy Terms and Conditions